Project

Wind generator

micfil ultra fine filters for gear oil

micfil ST300 double system for gear oil

Oil analysis for gear oil in wind generator

Before and after installation of micfil ultra fine filters – Number of particles in 10 ml oil

Particle size in microns> 4> 6> 10> 14> 21> 37TotalWater (ppm)Degree of purity
WITHOUT
Micfil Filter
177,30548,6016,5574,12845037237,07828121 / 19 / 16
WITH
Micfil Filter
13,9253,2461,547367572119,1635418 / 16 / 12
Reduction163,38045,3555,0103,76139316217,915227 3 / 3 / 4
Percent WITH Micfil Filter7.856.6823.598.8912.6756.768.0819.22
Reduction in percent92.1593.3276.4191.1187.3343.24
91.9280.78

Oil analysis in May 2009